Impingement monitoring studies: P.H. Robinson Generating Station, Houston Lighting and Power Company. Final report

Date

1980

Authors

Greene, G.N.
McAden, D.C.
Loyd, G.E.
Palermo, J.A.

Journal Title

Journal ISSN

Volume Title

Publisher

Houston Lighting and Power Company

Abstract

Houston Lighting & Power Company (HL&P) instituted an in-house study of revolving screen impingement at the P.H. Robinson Generating Station near Bacliff, Texas, in order to fulfill requirements of the Federal Water Pollution Control Act. The program began on 11 April 1978 and continued through 29 March 1979, with samples being collected every two weeks during this period. Environmental Protection department personnel of HL&P performed impingement sampling, identification, data analysis and reporting on all samples collected.

Description

138 p.

Keywords

water filters, pump stations, biology, surveys, water pollution, environmental effects, methodology, impingement