Abstract
The purpose of the project described was to investigate the relationship of ambient air quality measurements between two analytical methods, referred to as the total oxidant method and the chemiluminescent method. These two well documented analytical methods were run simultaneously, side by side, at a site on the Houston Ship Channel. They were calibrated daily. The hourly averages were analyzed by regression techniques and the confidence intervals were calculated for the regression lines. Confidence intervals for point estimates were also calculated.
Description
p. 394-396.
Keywords
chemiluminescence, air pollution, atmospheric chemistry, ozone, air quality