Calibration study on a prototype of the Muon Telescope Detector at STAR of RHIC

Show full item record

Title: Calibration study on a prototype of the Muon Telescope Detector at STAR of RHIC
Author: Li, Liang, master of arts in physics
Abstract: A prototype of the Muon Telescope Detector (MTD ) was installed at STAR (Solenoidal Tracker at RHIC ) during run year 2007 . While the cosmic and beam tests showed a ~ 60 - 70 ps timing resolution for MTD , the actual performance in Au + Au collisions at STAR was found ~300 ps . In run year 10 STAR implemented a new electronics system for MTD and a cosmic ray trigger to study the performance of its several subsystems . With the cosmic ray data , this study shows that the timing resolution of MTD can reach 99 ps after a full calibration .
URI: http : / /hdl .handle .net /2152 /ETD -UT -2011 -12 -4739
Date: 2012-02-20

Citation

Calibration study on a prototype of the Muon Telescope Detector at STAR of RHIC. Master's thesis, University of Texas at Austin. Available electronically from http : / /hdl .handle .net /2152 /ETD -UT -2011 -12 -4739 .